Need Help RE: Omega Super charger

having trouble with burst disk leaking air. Last time I topped off my tank to 4500 psi no problems. Two weeks later it's time to top off tank again. Hook up take, open value to equalize pressure and burst disk is leaking air. Remove burst disk bolt and remove the disk (first pic is the first disk). Second picture is replacement disk on right and the old disk on left, notice the blister on the old disk. So I replace slightly tighten burst disk bolt, open tank value it gets to 1000 psi and air begins to hiss again from the burst disk area. I take a look and see the same blistering on the newly installed disk??!! (See third picture). So what gives?? Can anyone help me with this?





 
don't know, i've had mine about 6 months and i did burst one disk, replaced it and tighten everything back up and no more issues. I would check all your lines and fittings on the compressor hose. I had an issue with where i connect the tank to the house blew a seal there and had a leak when i fixed it i over tightened something and air would not go into the tank so it built up pressure really fast in the line, but my tank gauge read like 500 psi.
 
Take a look at the check valve under the cap on the top of the compressor, just beside the burst disc cap. Take the check valve out and look at it. If it is distorted or funny looking, replace it with one of the ones included in the parts kit included with the compressor. Then replace the burst disc and see if everything works better.