    I had a YH use for one year and rip, change it for a similar one with a digital panel, damn! Looks similar but a world of difference, much much better. 

    – temperature stays in the 45c range, yo do not get burned

    – digital panel, you can set whatever pressure up to 300b

    – better construction

    – moisture separator really works

    – air stinks much less (I use also filters)

    – it is a bit less noisier

    9 month now, cero issues but a busted oring. Is used for top off 6.8l and 9L scbas. Means about 30 min each time

    What is your new one? Link?  

    Link

    edosan
    Participant
    Member

    @30harry check the post just above yours

    Link

    biohazardman
    Participant
    Member

    I pulled the Newest Yong Heng back apart and sanded a few thousandths off of the top of the 2nd stage piston and threw it back together it has been werqing fine ever since even though I ran it without oil for a minute or two.  Thought the horrible noise it was making was the rod banging cuz I ran it without oil but looks as if it was actually faulty tolerances on the new 2nd stage piston.  It was to long and was banging on the head.  I am still waiting for the new piston and rod assembly I ordered weeks back to get here from China.  So it really did not matter if I trashed this one.  Glad I tried the experiment.