Search results for query: *

  1. G

    Compressor Safety

    Yes, but common sense isn't as common as it use to be!
  2. G

    Sig Sauer New to this just wanna be safe

    I don't know if your compressor directions mention this, but the bleed valve on the compressor should be opened when starting the compressor against pressure (a non-empty bottle) and once the compressor starts, close the bleed valve for the fill. If you have to stop the compressor during a...
  3. G

    Umarex Komplete Hammer Spring Adjuster Mod

    Just a follow-up to finalize: I decided that a small mod to the stock would simplify tuning matters greatly, so I drilled a small access hole in the stock for adjustment. The standard long allen wrench works perfectly. Now no longer necessary to detatch the stock for adjustment of the hammer.
  4. G

    N/A Slug Uniformity and Accuracy

    Before they came up with the slip-clutch adjustment on the barrel of the mics, 10 people taking readings with the same mics would come up with 10 different results. That was a major improvement along with the tenths vernier. Sill more accuracy than is needed for pellets and slugs, IMO. For...
  5. G

    N/A Slug Uniformity and Accuracy

    From some of my research, pellets and slugs are made to +- .001, so I doubt anybody needs a micrometer like the one pictured; I was just being a pain. I've had and used that mic for many years before retiring.
  6. G

    Chilling your tank before topping off

    Any pictures; I'm having a time visualizing the "first stage off loaded to a shop compressor."
  7. G

    N/A Slug Uniformity and Accuracy

    Are you sure you haven't mis-stated the units. 1 micron= 0.00003937in., so 5 microns =0.00019685in. (maybe 50 microns?) I doubt anyone molds to those tolerances, or sizes the slugs or pellets afterwards. The .22 sizer I have is 0.2245; I have to push the HAWKi pellets through, but the Apolo...
  8. G

    N/A Slug Uniformity and Accuracy

    Is this accurate enough for you?
  9. G

    N/A Slug Uniformity and Accuracy

    @CanMike and @Dstrac: I'm pretty new to airguns, so I con't have much experience with different brands. I have some .22 HAWKi Thunder 25.3 gn pellets, very uniform and accurate. They are at 0.214 at the nose and 0.225 at the skirt. I just received some Apolo 25 gn slugs, very uniform but run...
  10. G

    Umarex Komplete Hammer Spring Adjuster Mod

    Sorry, i edited the title to show Komplete.
  11. G

    Umarex Komplete Hammer Spring Adjuster Mod

    I originally changed the hammer spring tension by putting a small slug between the hammer and spring. To change tension I would have to disassemble the gun, remove the hammer-spring assembly and try different thickness slugs. I decided to make an adjustable setup, and this is what I came up...
  12. G

    Tuning General Operational and Math Question

    @AlanMcD Thank you for the detailed response. In the powder-burner pistol world, we call that a captive guide rod, not used for the same reason, obviously but the same principle involced in making them. Your explanations clear a lot of things up!
  13. G

    Tuning General Operational and Math Question

    Degassing port.
  14. G

    Tuning General Operational and Math Question

    I made my own unit to use temporarily until the Inspire Precision unit gets here, hopefully by Friday. If you want to see some targets from a .22 Komplete, go here: https://www.gatewaytoairguns.org/GTA/index.php?topic=219436.20 They seem to shoot above their pay grade.
  15. G

    Tuning General Operational and Math Question

    I'm running the complete with an air cartridge charged to 3000 psi; not the N2 cartridge. Also, being new to airguns, what exhaust port ( I plead ignorance)? I thought the barrel was the "exhaust port" after the pellet exited.
  16. G

    Tuning General Operational and Math Question

    Mine is the Umarex Komplete, and the other is the Diana Outlaw.
  17. G

    Tuning General Operational and Math Question

    I am new to airguns; what is an SSG? Also the gun in question is the inexpensive, Komplete. It is regulated at 1800 psi, though I have no way to verify it. I am very happy with it and am just trying to learn different ways of tuning it for higher power. Right now I'm getting about 32 fpe...
  18. G

    Tuning General Operational and Math Question

    Thanks for the link; that will keep me busy for sure!!
  19. G

    Tuning General Operational and Math Question

    No, totally different manufacturers and different guns.
  20. G

    Tuning General Operational and Math Question

    That's what has me puzzled. With the larger slug that I used in the hammer, I merely wasted air; the smaller slug kept about the same velocity, but I gained in number of shots. Does that mean that the plenum is too small and cannot provide enough air for the barrel length, basically emptying...